In a fixed installation the discharge pipe almost always runs via flanges. Here you will find the parts that go with them: from threaded flange to bolt set with gasket. All in the sizes that fit HOMA pumps and lifting stations.
Which version do you need?
- Threaded flange: to go from a thread to a flange, in galvanised steel or in stainless steel for aggressive water.
- Flange socket: connects a flange to a plain PVC or PE pipe (DN100/110 or DN150/160).
- Special flange TP28 or TP50: fits directly onto the discharge port of those pumps.
- 90° bend DN65 with flanges: for the bend directly after the pump or the coupling system.
- Bolt set with gasket: always order it with a flanged joint. Stainless bolts and the right gasket, so you do not have to go hunting for anything.
In practice a flanged joint often starts leaking because the bolts were tightened unevenly. Tighten them crosswise and in two rounds, and always use a new gasket.
Free advice?
Feel free to contact our customer service without obligation if you are not sure which size you need.